At least one mop basin will be required in or near the kitchen.
Commercial kitchen floor drain requirements.
Cpc 411 2 2 floor drains shall be installed in commercial kitchens cpc 411 4 floor shall slope to drain.
Floor drains need to be provided throughout the kitchen area.
Floor drains shall be installed in commercial kitchens floor shall slope to drain.
4 diameter alterations greater than 50 shall have accessible water closets urinals and lavs.
At least one handwashing lavatory will be required.
Floor surfaces shall be coved at the juncture of the floor and wall with a 3 8 inch minimum radius coving and shall extend up the wall at least 4 inches except in areas where food is stored only in unopened bottles cans cartons sacks or other original shipping containers.
An air gap or air break are both acceptable since there.
The kitchen generally requires one lavatory facility for washing hands and at least one mop basin will be required in the kitchen.
The drains must be separate not tied together.
In food prep areas fixture requirements may be dictated by the health codes.
140 degrees f hot water is required due to dishwashers requiring 180 degrees f water for final rinse and a booster.
Waste piping that intersects or is routed above or near food preparation or storage areas requires a protective drip pan or containment.
The refrigeration drain does not require an air gap.
Fixture type location and quality sanitary fixture requirements for customers and employees shall be permitted to be met with a single set of restrooms.